#1 India's Top IT Training Institute
×

About Uncodemy

Know more about who we are and what we stand for.

About Us

About Us

Discover our mission to equip individuals with essential IT skills and industry expertise.

Read More →
UnCodeMy Gallery

UnCodeMy Gallery

Explore highlights from our IT training sessions and success stories.

Read More →
Mentors

Mentors

Meet the industry experts who train and guide you through your course.

Read More →
Free Resources

Free Resources

Free tutorials, interview questions, tools and calculators to help you learn.

Explore →
×

Free Resources

Learn, practice and plan your career — bilkul free.

Tutorials

Tutorials

Step-by-step written tutorials to learn any technology at your own pace.

Read More →
Free Counselling

Free Counselling

Book a free video counselling session and pick the right course for you.

Read More →
Online Compiler

Online Compiler

Write, run and test your code online — no setup required.

Read More →
⚡ FREE · STEP-BY-STEP

AC Impedance & Phasor Calculator: Z, θ and Power

Find Z for series or parallel R, L, C at any frequency, or add, multiply and divide phasors.

  • 🔄 Rectangular ↔ polar
  • ⚡ P, Q, S and power factor
  • 📐 Impedance triangle

How to use the AC Impedance and Phasor Calculator

  1. 1. Pick a modeSeries RLC, parallel RLC or phasor maths.
  2. 2. Enter valuesR, L, C and f, or two phasors like 3+j4 and 10∠−30.
  3. 3. See the answerZ in both forms, θ, power factor, currents and a diagram.

How AC impedance is calculated

In AC circuits each element has an impedance: Z_R = R, Z_L = jωL and Z_C = 1/(jωC) = −j/(ωC), with ω = 2πf. Series impedances add: Z = R + j(XL − XC). For parallel branches, add the admittances: Y = 1/R + j(ωC − 1/ωL), then Z = 1/Y. In polar form |Z| = √(R² + X²) and θ = tan⁻¹(X/R). The power factor is cos θ, lagging for inductive circuits and leading for capacitive ones.

Worked example: R = 30 Ω in series with L = 127.3 mH at 50 Hz gives XL = 314.16 × 0.1273 = 40 Ω. So Z = 30 + j40 = 50∠53.13° Ω. On 230 V, I = 4.6 A, the power factor is 0.6 lagging, P = 635 W, Q = 846 VAR and S = 1.06 kVA.

Phasor maths tips for exams

  • Add and subtract in rectangular form. Multiply and divide in polar form (multiply magnitudes and add angles).
  • Two parallel impedances: Z = Z1Z2/(Z1 + Z2).
  • Check your calculator mode: angles here are in degrees.
  • In a series circuit VL and VC are 180° apart, so you cannot add their magnitudes directly.

Phasor mode accepts 3+j4, 3+4j, −j10, 5∠53.13 and 5<53.13.

Frequently asked questions

How do I enter a complex number?

Rectangular as 3+j4, 3+4j or −j10, and polar as 5∠53.13 or 5<53.13 (angle in degrees). SI prefixes such as 4.7k also work.

What if my circuit has no capacitor?

Leave C blank. Blank elements are treated as not present: a missing series element adds nothing, and a missing parallel branch is open.

What do lagging and leading mean?

Lagging means the current lags the voltage (inductive, θ > 0). Leading means the current leads the voltage (capacitive, θ < 0).

Is this tool free?

Yes. You fill in a short form once to see your result, and the other Uncodemy tools then open without it. All the maths runs in your browser.

More free tools

See all free tools